Explain centrifugal pump O/H. how to check trueness of shaft ?



1.80 K Views | Rishi Kashyap | ANSWER |
JAHAJEE.com user
1
X
0

Put off breaker and remove fuse from motor starter box
Close suction and discharge valve
Remove suction and discharge pipe flange bolt & nut, coupling bolt of motor coupling
Remove pump foundation bolts & take out pump from motor
Remove impeller lock & nut & take out the impeller
Remove mechanical seal.
Remove bearing cover from other side & take out shaft with ball bearing
Renew mechanical seal and bearings if required.
Clean and inspect all parts and assemble.

Sourabh Meena | | EDIT | REPLY


tags  MMD / MCA ORALS MEO CLASS 4 EXAM