How is the manhole door cut on the boiler steam drum ?
X 0
boiler manhole door cut in such a way that its longitudinal stress is proportional to the minor axis, elliptical in shape. to compensate the hoop stress( circumferential), also need to place the compensating ring near the area where the manhole door cuts, its thickness is same as the area of manhole door cuts...