ORAL
QUESTIONSADD YOUR
QUESTIONS
2ND MATE EXAM ORAL QUESTIONS AND ANSWERS BY CAPT-OAK - LATEST QUESTIONS
Q. 1) How many types of msi notices are there
XQ. 2) Sound signal vessel aground and at anchor
Xthree distinct strokes of the bell before and after rapid ringing of the bell for 5 seconds also can sound "U"
Q. 4) Bilge alarm requirements for bulk carriers as per SOLAS ch12 ?
Xaudible and visual alarm,one when the water level above the inner bottom in any hold reaches height of 0.5 m and another at a height not less than 15% of the depth of hold but not more than 2 m.
Q. 6) Angle of loll and wall sided formula
XQ. 8) Special areas for annex vi any new ammendments
Xbaltic sea,north sea,
we present amendments of Marpol Annex VI regulations 2,6,12,13,14,15 and 16. Amendments are effective as from 1 July 2010.
Q. 9) Starting procedure for an emg. fire pump
X1, open 1 or 2 hydrants on deck or anchor wash
2, open suction valve
3, shut discharge valve
4, check hadder tank fr primming
5, check the fuel tanks
6, rotate the hand wheel crank shaft for atleast 2 min
7, adjust the decompressor lever
8, as soon as you seen the pressure raising in pressure guage open the discharge valve