While dischaging in a tanker you obsereve tank pressures reducing. what are dpossible reasons and how ? explain your actions as



472 Views | Binu George | ANSWER |
JAHAJEE.com user
1
X
0

when disch igs is supplying inert gas contonously to da tanks so may be igs is not working or experiencing problems or pv v/vs having a leakage

Mandar Mhamunkar | | EDIT | REPLY

JAHAJEE.com user
1
X
0

may be the vaccum side of the pv valve is not working or , the vrl if used, the valve of the vrl is not opened or the vrl line is chocked by some solidifying cargo like hmd or the tank pressure sensor is not working prperly ... these or some possible ways.

Jude Buy | | EDIT | REPLY
JAHAJEE.com user
1
X
0

may the ig pressure not coping with disch rate .

Ganesh Nirmal | | EDIT | REPLY
JAHAJEE.com user
136
X
0

check venting system , may be some vent open if falling slowly , drastic redustion I.G stopped ....  if vent open close it ... ig failure inform E/R ... ALL  CASES CALL C/O....This is wat is expected ...

Naveen Bijarania | | EDIT | REPLY