MMD / MCA ORALS >> 2nd Mate Exam oral questions and answers
ORAL
QUESTIONS
ADD YOUR
QUESTIONS
Examination Center
Surveyor
Functions
ARRANGE
 

2ND MATE EXAM ORAL QUESTIONS AND ANSWERS - LATEST QUESTIONS | Page 89




X Q / Ans may be for a particular Surveyor. Please select Surveyor !
Asked 1 time (Latest on 21-Aug-2011)

Q. 881) What do mean by drop anchor by foot

X
    Dhinesh Ruba
    16
    X
    3

    DROP AN ANCHOR UNDERFOOT: LETTING AN ANCHOR GO TO THE BOTTOM, THEN HOLDINGON TO THE BRAKE. THIS IS SOMETIMES DON’T TO STEADY THE SHIPS HEAD AND PREVENT HER FROM YAWING ABOUT WHEN LYING TO A SINGLE ANCHOR

    Dhinesh Ruba | | EDIT | REPLY



      Asked 1 time (Latest on 21-Aug-2011)

      Q. 882) What is use of a willdon pump in sopep locker ?

      X
        Vivek Misra
        26
        X
        0

        whenevr ther is leakge onboard , use wildon pump to collect that oil n store it either in drums or in the slop tanks.

        Vivek Misra | | EDIT | REPLY

          Asked 1 time (Latest on 01-May-2011)

          Q. 883) Hw to esume cargo operation wen your PV breakers blows nd you do not hav glycol ?

          X
            Answer this MMD / MCA Oral Question

            Asked 1 time (Latest on 01-May-2011)

            Q. 884) Discharge criterea for annex 5

            X
              Answer this MMD / MCA Oral Question

              Asked 1 time (Latest on 01-May-2011)

              Q. 885) During loading your PV breaker blows ? actions ?

              X
                JAHAJEE.com user
                1
                X
                0

                Stop Loading. Let the pressure of tank falls to level below the pressure setting of PV valve. Close individual tank IG branch valve.Verify the Cause of Over pressurization of Tanks. Fill up PV breaker (Glycol + water) and resume loading
                Remember to check the Pressure sensor setting installed in each tanks after sailing  

                Pradeep Yadav | | EDIT | REPLY

                  Asked 1 time (Latest on 01-May-2011)

                  Q. 886) What is passivation ?

                  X
                    Azad Chauhan
                    1
                    X
                    0

                    Passivation is the process of making a material "passive", usually by the deposition of a layer of oxide on its surface. In...

                    Azad Chauhan | | EDIT | REPLY

                      Asked 1 time (Latest on 01-May-2011)

                      Q. 887) L / b lowering frequencies . all

                      X
                        Vivek Misra
                        26
                        X
                        0

                        to deck level evry month
                        to water level evry 3 months

                        Vivek Misra | | EDIT | REPLY

                          Asked 1 time (Latest on 01-May-2011)

                          Q. 888) While dischaging in a tanker you obsereve tank pressures reducing. what are dpossible reasons and how ? explain your actions as

                          X
                            JAHAJEE.com user
                            1
                            X
                            0

                            when disch igs is supplying inert gas contonously to da tanks so may be igs is not working or experiencing problems or pv v/vs having a leakage

                            Mandar Mhamunkar | | EDIT | REPLY
                              JAHAJEE.com user
                              1
                              X
                              0

                              may be the vaccum side of the pv valve is not working or , the vrl if used, the valve of the vrl is not opened or the vrl line is chocked by some solidifying cargo like hmd or the tank pressure sensor is not working prperly ... these or some possible ways.

                              Jude Buy | | EDIT | REPLY
                                JAHAJEE.com user
                                1
                                X
                                0

                                may the ig pressure not coping with disch rate .

                                Ganesh Nirmal | | EDIT | REPLY
                                  JAHAJEE.com user
                                  136
                                  X
                                  0

                                  check venting system , may be some vent open if falling slowly , drastic redustion I.G stopped ....  if vent open close it ... ig failure inform E/R ... ALL  CASES CALL C/O....This is wat is expected ...

                                  Naveen Bijarania | | EDIT | REPLY

                                    Asked 1 time (Latest on 01-May-2011)

                                    Q. 889) What is damage stability manual ?

                                    X
                                      Arunkumar Moorthy
                                      11
                                      X
                                      0

                                      It contains stability of ship during its damaged condition and capacity to resist damage situation caused by flooding due to the water overflow into bilges

                                      Arunkumar Moorthy | | EDIT | REPLY

                                        Asked 2 time (Latest on 01-May-2011)

                                        Q. 890) How will you test loadicator ? nd wen ?

                                        X
                                          Vivek Misra
                                          26
                                          X
                                          1

                                          -FOLLOW THE INSTRUCTION MANUAL FROM THE MANUFACTURE
                                          -EVRY MONTH
                                          -SIGN/FILE THE TEST REPORT

                                          Vivek Misra | | EDIT | REPLY


                                            SHARE Whatsapp Facebook Twitter To TOP