MMD / MCA ORALS >> 2nd Mate Exam oral questions and answers
ORAL
QUESTIONS
ADD YOUR
QUESTIONS
Examination Center
Surveyor
Functions
ARRANGE
 

2ND MATE EXAM ORAL QUESTIONS AND ANSWERS BY CAPT-PANDE - LATEST QUESTIONS



DOWNLOAD

Asked 1 time (Latest on 01-May-2011)

Q. 1) L / b lowering frequencies . all

X
    X
    0

    to deck level evry month
    to water level evry 3 months

    Vivek Misra | 8 years ago | EDIT | REPLY




      Asked 1 time (Latest on 01-May-2011)

      Q. 2) Discharge criterea for annex 5

      X
        Answer this MMD / MCA Oral Question

        Asked 1 time (Latest on 01-May-2011)

        Q. 3) While dischaging in a tanker you obsereve tank pressures reducing. what are dpossible reasons and how ? explain your actions as

        X
          X
          0

          when disch igs is supplying inert gas contonously to da tanks so may be igs is not working or experiencing problems or pv v/vs having a leakage

          Mandar Mhamunkar | 8 years ago | EDIT | REPLY
            X
            0

            may be the vaccum side of the pv valve is not working or , the vrl if used, the valve of the vrl is not opened or the vrl line is chocked by some solidifying cargo like hmd or the tank pressure sensor is not working prperly ... these or some possible ways.

            Jude Buy | 8 years ago | EDIT | REPLY
              X
              0

              may the ig pressure not coping with disch rate .

              Ganesh Nirmal | 8 years ago | EDIT | REPLY
                X
                0

                check venting system , may be some vent open if falling slowly , drastic redustion I.G stopped ....  if vent open close it ... ig failure inform E/R ... ALL  CASES CALL C/O....This is wat is expected ...

                Naveen Bijarania | 8 years ago | EDIT | REPLY

                  Asked 1 time (Latest on 01-May-2011)

                  Q. 4) During loading your PV breaker blows ? actions ?

                  X
                    X
                    0

                    Stop Loading. Let the pressure of tank falls to level below the pressure setting of PV valve. Close individual tank IG branch valve.Verify the Cause of Over pressurization of Tanks. Fill up PV breaker (Glycol + water) and resume loading
                    Remember to check the Pressure sensor setting installed in each tanks after sailing  

                    Pradeep Yadav | 4 years ago | EDIT | REPLY

                      Asked 1 time (Latest on 01-May-2011)

                      Q. 5) How will you test loadicator ? nd wen ?

                      X
                        X
                        1

                        -FOLLOW THE INSTRUCTION MANUAL FROM THE MANUFACTURE
                        -EVRY MONTH
                        -SIGN/FILE THE TEST REPORT

                        Vivek Misra | 8 years ago | EDIT | REPLY

                          Asked 1 time (Latest on 01-May-2011)

                          Q. 6) Special areas of MARPOL annex 1 & 5

                          X
                            X
                            0

                            ANNEX-1   Mediterranean, baltic,black,red seas,gulf areas, gulf of aden, antartic areas,NW european waters,omen areas of arabian sea,southern south african waters


                            ANNEX-2
                            Mediterranean, baltic,black,red seas,gulf areas,north sea,Antarctic area (south
                            of latitude 60
                            degrees south),Wider Caribbean
                            region including the
                            Gulf of Mexico and
                            the Caribbean Sea,

                            Jagades Babu | 8 years ago | EDIT | REPLY

                              Asked 1 time (Latest on 01-May-2011)

                              Q. 7) What is passivation ?

                              X
                                X
                                0

                                Passivation is the process of making a material "passive", usually by the deposition of a layer of oxide on its surface. In...

                                Azad Chauhan | 8 years ago | EDIT | REPLY

                                  Asked 1 time (Latest on 01-May-2011)

                                  Q. 8) Hw to esume cargo operation wen your PV breakers blows nd you do not hav glycol ?

                                  X
                                    Answer this MMD / MCA Oral Question

                                    Asked 1 time (Latest on 01-May-2011)

                                    Q. 9) What is damage stability manual ?

                                    X
                                      X
                                      0

                                      It contains stability of ship during its damaged condition and capacity to resist damage situation caused by flooding due to the water overflow into bilges

                                      Arunkumar Moorthy | 8 years ago | EDIT | REPLY

                                        Asked 1 time (Latest on 02-Mar-2011)

                                        Q. 10) Solas regulation for life boat falls ?

                                        X
                                          X
                                          0

                                          "the falls shall be turned end for end at intervals of not more than 30 months and be renewed when necessary, due to deterioration of the falls or at intervals of not more than five years, whichever is the earlier".

                                          Jagades Babu | 8 years ago | EDIT | REPLY

                                            DOWNLOAD